Water Chemistry

Check water chemistry regularly and maintain within recommended levels. Standards vary in different residential and commercial applications. Follow all local applicable codes.

NOTICE

- Failure to heed the following may result in damage to equipment.

 

  • Do not allow water to flow through heat pump when refinishing or acid washing a pool. Either use an installed bypass to route water away from heat pump or deactivate filter pump.
  • To avoid damage to equipment, monitor and maintain chemistry within recommended levels.

CHEMISTRY LEVEL CHART

(RESIDENTIAL)

CHEMICAL POOLS SPAS
Chlorine 1.0 – 3.0 ppm 3.0 – 5.0 ppm
Bromine 2.0 – 6.0 ppm 2.0 – 6.0 ppm
Cyanuric Acid 30 – 50 ppm 30 – 50 ppm
pH 7.4 – 7.6 ppm 7.4 – 7.6 ppm
Total Alkalinity 80 – 120 ppm 80 – 120 ppm
Calcium Hardness 200 – 400 ppm 150 – 250 ppm
Total Dissolved Solids* 0 – 1,500 ppm 1,500 ppm above start-up of total dissolved solids in spas
* Salt from a chlorine generator is not included in Total Dissolved Solids.